5/5.8kW Single-Phase Monitored PDU, LX Interface, 208/240V Outlets (36 C13/6 C19), L6-30P, 10 ft. Cord, 0U 1.8m/70 in. Height, TAA
The PDUMNV30HV2LX 5.8kW Single-Phase Monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via built-in network connection. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime.

The 0U PDU features 42 outlets (36 C13 and 6 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A 10-foot cord with NEMA L6-30P plug connects the PDU to a compatible AC power source, generator or protected UPS.

The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

A digital ammeter allows you to monitor each load bank’s current and the total connected PDU load in real time to ensure they remain well below maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.

Distributes and Monitors Network-Grade Single-Phase Power
- 5/5.8kW 208/240V monitored PDU with single-phase input
- NEMA L6-30P plug with 10 ft. cord connects to compatible AC power source
- Firmware upgrades support future product enhancements

42 Outlets Distribute AC Power
- 36 C13 and 6 C19 outlets split into 2 separately breakered 20A load banks
- Plug-lock insert sleeves prevent cables from becoming accidentally disconnected

Digital Ammeter
- Reports current for each load bank and total connected PDU load
- Supports IP-address self-ID
- Rotates 180° for easy reading at either angle

Built-In LX Platform Interface
- Allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH
- Supports 10/100 Mbps auto-sensing for communication with an Ethernet network
- Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities
- No Java required

Broad Communications Compatibility
- Supports IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP
- Supports automatic and manual assignment of IP address

Essential Safety Features
- Tiered access allows administrator and guest to log in via web browser
- Immediate alert notifications via email or SNMP traps
- Supports user-specified alarm notification thresholds
- Real-time clock backup maintains day/date even if PDU is unpowered

Easy 0U Installation in EIA-Standard 19 in. Racks
- Mounts vertically using included toolless buttons or rack-mounting brackets
- Included PDUMVROTATEBRKT allows mounting with rear-facing outlets

TAA-Compliant
- Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
More Information
SKU PDUMNV30HV2LX
EAN 0037332204486
Specification
Design
PDU typesMonitored
MountingVertical
On/off switchYes
TypeSingle-phase
DisplayLCD
Product colourBlack
CertificationUL60950-1: 2007 (USA) CAN/CSA-C22.2 NO. 60950-1-07 (Canada) FCC Class A Part 15 (Emissions) NOM (Mexico) TAA Compliant
Rack capacity0U
Ports & interfaces
Power plugNEMA L6-30P
AC outlets quantity42 AC outlet(s)
Master AC outlets quantity36
Slave AC outlets quantity6
AC outlet typesC13 coupler, C19 coupler
Features
LED indicatorsYes
CertificationUL60950-1: 2007 (USA) CAN/CSA-C22.2 NO. 60950-1-07 (Canada) FCC Class A Part 15 (Emissions) NOM (Mexico) TAA Compliant
Management features
Supported network protocolsIPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP
MonitoringCurrent, Power
Ergonomics
DisplayLCD
LED indicatorsYes
Power
Nominal input voltage200-240 V
Maximum power5800 W
Maximum current30 A
Nominal output voltage200-240 V
AC input frequency50 - 60 Hz
Weight & dimensions
Dimensions (WxDxH)2.2 x 2.64 x 70" (56 x 67 x 1778 mm)
Weight15 lbs (6.8 kg)
Width2.19" (55.6 mm)
Depth2.65" (67.3 mm)
Height70.5" (1790.7 mm)
Package width5.79" (147.1 mm)
Package depth72.5" (1841.5 mm)
Package height4.25" (108 mm)
Package weight16.5 lbs (7.48 kg)
Package dimensions (WxDxH)5.79 x 4.29 x 72.5" (147 x 109 x 1842 mm)
Packaging data
Package width5.79" (147.1 mm)
Package depth72.5" (1841.5 mm)
Package height4.25" (108 mm)
Package weight16.5 lbs (7.48 kg)
Package dimensions (WxDxH)5.79 x 4.29 x 72.5" (147 x 109 x 1842 mm)
Packaging content
ManualYes
Operational conditions
Storage temperature (T-T)-15 - 60 °C
Operating relative humidity (H-H)5 - 95%
Operating altitude0 - 118110.2" (0 - 3000 m)
Operating temperature (T-T)5 - 140 °F
Technical details
Sustainability certificatesRoHS
Logistics data
Master (outer) case width5.79" (147.1 mm)
Master (outer) case length72.5" (1841.5 mm)
Master (outer) case height4.25" (108 mm)
Master (outer) case gross weight16.5 lbs (7.48 kg)
Products per master (outer) case1 pc(s)
Country of originTaiwan
Manufacturer Tripp Lite
PDF Url https://objects.icecat.biz/objects/
Related Products