3.8kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V C20 Inlets, 8 C13 & 2 C19 Outputs, 1U, TAA
This Switched Automatic Transfer Switch / ATS PDU provides a redundant power option for single-corded network devices. Dual input cords support separate connection to primary and secondary power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. SmartOnline® series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separate) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
More Information
SKU PDUMH20HVATNET
EAN 0037332151506
Specification
Design
PDU typesSwitched
MountingHorizontal
Product colourBlack
CertificationUL 60950 (USA, Canada), CE (Europe), Class A (Emissions), NOM (Mexico)
Rack capacity1U
Housing materialMetal
Ports & interfaces
Power plugC20 coupler
AC outlets quantity10 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler
Features
LED indicatorsYes
Cable length141.7" (3.6 m)
CertificationUL 60950 (USA, Canada), CE (Europe), Class A (Emissions), NOM (Mexico)
Ergonomics
LED indicatorsYes
Cable length141.7" (3.6 m)
Power
Nominal input voltage200-240 V
Maximum current20 A
Nominal output voltage200-240 V
AC input frequency50 - 60 Hz
Weight & dimensions
Dimensions (WxDxH)17.3 x 14.8 x 1.73" (439 x 376 x 44 mm)
Weight10.3 lbs (4.69 kg)
Width17.3" (440.2 mm)
Depth14.8" (375.2 mm)
Height1.72" (43.7 mm)
Package width20.8" (528.3 mm)
Package depth23.4" (594.4 mm)
Package height5.4" (137.2 mm)
Package weight17 lbs (7.71 kg)
Packaging data
Package width20.8" (528.3 mm)
Package depth23.4" (594.4 mm)
Package height5.4" (137.2 mm)
Package weight17 lbs (7.71 kg)
Operational conditions
Storage temperature (T-T)-15 - 50 °C
Operating altitude0 - 118110.2" (0 - 3000 m)
Technical details
Sustainability certificatesRoHS
Logistics data
Products per master (outer) case1 pc(s)
Country of originTaiwan
Manufacturer Tripp Lite